How do Temperature Controllers work?
To accurately control process temperature without extensive operator involvement, a temperature control system relies upon a controller, which accepts a temperature sensor such as a thermocouple or RTD as input. It compares the actual temperature to the desired control temperature, or setpoint, and provides an output to a control element. The controller is one part of the entire control system, and the whole system should be analyzed in selecting the proper controller. The following items should be considered when selecting a controller:
  1. Type of input sensor (thermocouple, RTD) and temperature range
  2. Type of output required (electromechanical relay, SSR, analog output)
  3. Control algorithm needed (on/off, proportional, PID)
  4. Number and type of outputs (heat, cool, alarm, limit)
  5. What Are the Different Types of Controllers, and How Do They Work?
    There are three basic types of controllers: on-off, proportional and PID. Depending upon the system to be controlled, the operator will be able to use one type or another to control the process.

    On/Off Control
    An on-off controller is the simplest form of temperature control device. The output from the device is either on or off, with no middle state. An on-off controller will switch the output only when the temperature crosses the setpoint. For heating control, the output is on when the temperature is below the setpoint, and off above setpoint. Since the temperature crosses the setpoint to change the output state, the process temperature will be cycling continually, going from below setpoint to above, and back below. In cases where this cycling occurs rapidly, and to prevent damage to contactors and valves, an on-off differential, or “hysteresis,” is added to the controller operations. This differential requires that the temperature exceed setpoint by a certain amount before the output will turn off or on again. On-off differential prevents the output from “chattering” or making fast, continual switches if the cycling above and below the setpoint occurs very rapidly. On-off control is usually used where a precise control is not necessary, in systems which cannot handle having the energy turned on and off frequently, where the mass of the system is so great that temperatures change extremely slowly, or for a temperature alarm. One special type of on-off control used for alarm is a limit controller. This controller uses a latching relay, which must be manually reset, and is used to shut down a process when a certain temperature is reached.

    Proportional Control
    Proportional controls are designed to eliminate the cycling associated with on-off control. A proportional controller decreases the average power supplied to the heater as the temperature approaches setpoint. This has the effect of slowing down the heater so that it will not overshoot the setpoint, but will approach the setpoint and maintain a stable temperature. This proportioning action can be accomplished by turning the output on and off for short time intervals. This "time proportioning" varies the ratio of “on” time to "off" time to control the temperature. The proportioning action occurs within a “proportional band” around the setpoint temperature. Outside this band, the controller functions as an on-off unit, with the output either fully on (below the band) or fully off (above the band). However, within the band, the output is turned on and off in the ratio of the measurement difference from the setpoint. At the setpoint (the midpoint of the proportional band), the output on:off ratio is 1:1; that is, the on-time and off-time are equal. if the temperature is further from the setpoint, the on- and off-times vary in proportion to the temperature difference. If the temperature is below setpoint, the output will be on longer; if the temperature is too high, the output will be off longer.

    PID Control
    The third controller type provides proportional with integral and derivative control, or PID. This controller combines proportional control with two additional adjustments, which helps the unit automatically compensate for changes in the system. These adjustments, integral and derivative, are expressed in time-based units; they are also referred to by their reciprocals, RESET and RATE, respectively. The proportional, integral and derivative terms must be individually adjusted or “tuned” to a particular system using trial and error. It provides the most accurate and stable control of the three controller types, and is best used in systems which have a relatively small mass, those which react quickly to changes in the energy added to the process. It is recommended in systems where the load changes often and the controller is expected to compensate automatically due to frequent changes in setpoint, the amount of energy available, or the mass to be controlled.
    OMEGA offers a number of controllers that automatically tune themselves. These are known as autotune controllers.

    Standard Sizes
    Since temperature controllers are generally mounted inside an instrument panel, the panel must be cut to accommodate the temperature controller. In order to provide interchangeability between temperature controllers, most temperature controllers are designed to standard DIN sizes. The most common DIN sizes are shown below.
    Standard DIN Cutouts for Temperature Controllers

     

    http://www.omega.com/prodinfo/temperaturecontrollers.html

?

List of Articles
번호 분류 제목 글쓴이 날짜 조회 수
공지 회사 목록 모아레 2011.02.07 22930
공지 메모 연락처 목록 모아레 2010.08.05 1877
공지 메모 유용한 사이트 모아레 2010.02.25 9252
공지 메모 메모 정리 (미완) 모아레 2009.10.30 781
공지 메모 연구실 장비 목록 모아레 2009.09.30 2550
공지 메모 주문, 구입 리스트 모아레 2009.09.21 1172
공지 메모 To do list, Short Memo 모아레 2009.08.20 1563
92 MALDI 설명 모아레 2011.02.13 14883
91 PS/2 케이블 and 어댑터 모아레 2011.02.07 1561
90 XML 강좌 모아레 2011.02.07 473
89 참고 사이트 모아레 2011.02.01 349
88 자료 반도체 기초자료 - Lithography 등 모아레 2011.01.17 542
87 메모 AlN properties, Resonance 기초 모아레 2010.12.13 874
86 메모 Nonlinear resonance 모아레 2010.11.30 489
85 메모 컴퓨터 오류 모아레 2010.11.15 392
84 자료 Piezoelectric materials 모아레 2010.11.12 396
83 메모 Etch rate of GaAs 모아레 2010.11.10 379
82 자료 Noise (in audio amplifiers) 모아레 2010.10.08 1082
81 메모 KPS 초록 모아레 2010.10.02 886
80 자료 Solution of an eigenfrequency problem 모아레 2010.10.02 975
» 자료 Introduction to Temperature Controllers 모아레 2010.09.14 1165
78 자료 (에소 머신을 위한) PID 장착 방법! 모아레 2010.09.13 1642
77 메모 ZnO Nanowire COMSOL Simulation 참고 모아레 2010.09.11 769
76 메모 pirahna solution 모아레 2010.09.01 341
75 메모 COMSOL 교육 결제 공지 모아레 2010.08.23 610
74 자료 Anodic Aluminum Oxide(AAO) 연구 분야 모아레 2010.08.21 643
73 메모 About Network Analyzer Calibration 모아레 2010.08.16 508
Board Pagination Prev 1 2 3 4 ... 5 Next
/ 5