메뉴 건너뛰기

OBG

연구실

자료 SEM specification

모아레 2010.01.26 00:27 조회 수 : 12108

http://www.geos.ed.ac.uk/facilities/sem/specification.html

 

The SEM facility operates a Philips XL30CP with PGT Spirit X-ray analysis and HKL Channel5 Electron Backscatter Diffraction (EBSD) systems. The specification of the instrument is:

  • Electron Gun: A tungsten filament source produces a stable and high current electron beam, ideal for x-ray analysis as well as imaging.
  • Resolution: The resolution of the microscope is 3.5nm at 30kV using the secondary electron (SE) detector.
  • Backscatter: The backscatter (BSE) detector allows the imaging of specimens that have a mean atomic number difference of >0.1.
  • Cathodoluminescence: The Philips cathodoluminescence (CL) detector has a spectral response of 20%QE from 275 to 600nm.
  • Controlled pressure: The specimen chamber pressure may be controlled in the range from 0.1 to 1mBar, allowing the analysis and (BSE) imaging of insulators, hydrated samples or uncoated specimens without charging artifacts.
  • Stage: 50*50mm eucentric stage featuring motorised control of x, y, z and rotation.
  • The PGT Spirit EDS X-ray anlysis system allows qualitative and quantitative analysis as well as X-ray imaging of samples. The energy dispersive X-ray detector can detect elements heavier than and including Carbon.
  • The HKL Channel5 EBSD system enables the determination of crystallographic orientation data.
  • Images: All images may be stored using either a high resolution digital frame store (1404*968 or 702*484) or high resolution phototube. Digital (.tif) images may be exported to CD or USB memory stick. Output devices include a laser printer and a thermal video printer.
  • Operating System: All microscope, X-ray and EBSD analysis systems operate via a computer using the Windows operating system.
  • The Facility also has the necessary support equipment:

    • Sample preparation including impregnation, cutting, grinding and polishing equipment.
    • Carbon and Gold coating.
    • Reflected and transmitted light microscopes with photographic facilities for specimen documentation.
    • Optical cathodoluminescence microscope.
    • Black & White photographic developing and printing facilities.
    • Access to the Electron Microprobe Facility for quantitative major and minor element (0.01 wt%) analysis using either energy dispersive analysis or wavelength dispersive analysis.
    • Access to the Ion Microprobe Facility for isotopic and trace element (ppm) analysis.
번호 제목 글쓴이 날짜 조회 수
공지 회사 목록 모아레 2011.02.07 17017
공지 연락처 목록 모아레 2010.08.05 277
공지 유용한 사이트 모아레 2010.02.25 5339
공지 메모 정리 (미완) 모아레 2009.10.30 204
공지 연구실 장비 목록 모아레 2009.09.30 802
공지 주문, 구입 리스트 모아레 2009.09.21 446
공지 To do list, Short Memo 모아레 2009.08.20 449
92 MALDI 설명 모아레 2011.02.13 14481
» SEM specification 모아레 2010.01.26 12108
90 [사람과 이야기] 방학을 잊은 교수들… "과학에 희망 있어요" [1] 모아레 2010.01.03 5984
89 아세톤 메탄올 IPA 사용에 관한 포스트 모아레 2009.08.18 5195
88 반도체공동연구소(반공연) 공정접수 내용 모아레 2010.02.01 3627
87 A huge quantum resonator 모아레 2010.03.24 3314
86 교내개발 소프트웨어 배포 - snu메일 모아레 2010.02.23 1948
85 연구실 서버를 위한 리눅스 관리 가이드 모아레 2009.11.10 1934
84 라만 측정의 이해 모아레 2010.05.10 1906
83 로타리펌프 견적서관련 모아레 2009.08.20 1781
82 Al2O3 etch 모아레 2010.07.19 1620
81 Lieber Appointed Coeditor Of Nano Letters 모아레 2009.10.26 1614
80 BOE(Buffered oxide etch) 모아레 2010.01.11 1336
79 어디서 먼지들이 샘플에 다닥다닥붙는지 체크할것 모아레 2010.02.20 1204
78 PS/2 케이블 and 어댑터 모아레 2011.02.07 1154
77 (에소 머신을 위한) PID 장착 방법! 모아레 2010.09.13 1043
76 연구실에서 구입했었던 모니터, 외장하드디스크, 하드디스크 모아레 2009.08.07 916
75 오실로스코프의 이해와 올바른 사용법 모아레 2009.09.13 708
74 how to confirm the impedance of the microstrip? 모아레 2010.07.10 567
73 Introduction to Temperature Controllers 모아레 2010.09.14 518