http://www.geos.ed.ac.uk/facilities/sem/specification.html
The SEM facility operates a Philips XL30CP with PGT Spirit X-ray analysis and HKL Channel5 Electron Backscatter Diffraction (EBSD) systems. The specification of the instrument is:
- Electron Gun: A tungsten filament source produces a stable and high current electron beam, ideal for x-ray analysis as well as imaging.
- Resolution: The resolution of the microscope is 3.5nm at 30kV using the secondary electron (SE) detector.
- Backscatter: The backscatter (BSE) detector allows the imaging of specimens that have a mean atomic number difference of >0.1.
- Cathodoluminescence: The Philips cathodoluminescence (CL) detector has a spectral response of 20%QE from 275 to 600nm.
- Controlled pressure: The specimen chamber pressure may be controlled in the range from 0.1 to 1mBar, allowing the analysis and (BSE) imaging of insulators, hydrated samples or uncoated specimens without charging artifacts.
- Stage: 50*50mm eucentric stage featuring motorised control of x, y, z and rotation.
- The PGT Spirit EDS X-ray anlysis system allows qualitative and quantitative analysis as well as X-ray imaging of samples. The energy dispersive X-ray detector can detect elements heavier than and including Carbon.
- The HKL Channel5 EBSD system enables the determination of crystallographic orientation data.
- Images: All images may be stored using either a high resolution digital frame store (1404*968 or 702*484) or high resolution phototube. Digital (.tif) images may be exported to CD or USB memory stick. Output devices include a laser printer and a thermal video printer.
- Operating System: All microscope, X-ray and EBSD analysis systems operate via a computer using the Windows operating system.
- Sample preparation including impregnation, cutting, grinding and polishing equipment.
- Carbon and Gold coating.
- Reflected and transmitted light microscopes with photographic facilities for specimen documentation.
- Optical cathodoluminescence microscope.
- Black & White photographic developing and printing facilities.
- Access to the Electron Microprobe Facility for quantitative major and minor element (0.01 wt%) analysis using either energy dispersive analysis or wavelength dispersive analysis.
- Access to the Ion Microprobe Facility for isotopic and trace element (ppm) analysis.
The Facility also has the necessary support equipment:
댓글 0
번호 | 제목 | 글쓴이 | 날짜 | 조회 수 |
---|---|---|---|---|
공지 | 회사 목록 | 모아레 | 2011.02.07 | 17786 |
공지 | 연락처 목록 | 모아레 | 2010.08.05 | 288 |
공지 | 유용한 사이트 | 모아레 | 2010.02.25 | 5529 |
공지 | 메모 정리 (미완) | 모아레 | 2009.10.30 | 211 |
공지 | 연구실 장비 목록 | 모아레 | 2009.09.30 | 808 |
공지 | 주문, 구입 리스트 | 모아레 | 2009.09.21 | 452 |
공지 | To do list, Short Memo | 모아레 | 2009.08.20 | 455 |
12 | COMSOL 시뮬레이션 참고자료 | 모아레 | 2009.07.30 | 89 |
11 | 옥스포드 트랜스포트 튜브 거는 것 관련 | 모아레 | 2009.07.28 | 79 |
10 | 연구실 공유기, 프린터 공유 설정 | 모아레 | 2009.07.19 | 473 |
9 | 레지스트 조사 | 모아레 | 2009.07.19 | 119 |
8 | 옥스포드장비에 연결할 어댑터 맡겨놨음 | 모아레 | 2009.07.15 | 319 |
7 | CNT 성질 연구 | 모아레 | 2009.07.08 | 52 |
6 | Litho 관련 용어 정리 | 모아레 | 2009.07.08 | 104 |
5 | 충남대 물리학과 안교수님 연구실 정보 | 모아레 | 2009.07.02 | 76 |
4 | Synchronized Oscillation in Coupled Nanomechanical Oscillators - 심승보 | 모아레 | 2009.06.30 | 276 |
3 | comsol 관리 기록 | 모아레 | 2009.06.29 | 80 |
2 | 연구실 연락처 | 모아레 | 2009.06.23 | 117 |
1 | High-frequency micromechanicl resonators form aluminium-carbon nanotube nanolaminates | 모아레 | 2009.06.17 | 297 |