http://www.geos.ed.ac.uk/facilities/sem/specification.html
The SEM facility operates a Philips XL30CP with PGT Spirit X-ray analysis and HKL Channel5 Electron Backscatter Diffraction (EBSD) systems. The specification of the instrument is:
- Electron Gun: A tungsten filament source produces a stable and high current electron beam, ideal for x-ray analysis as well as imaging.
- Resolution: The resolution of the microscope is 3.5nm at 30kV using the secondary electron (SE) detector.
- Backscatter: The backscatter (BSE) detector allows the imaging of specimens that have a mean atomic number difference of >0.1.
- Cathodoluminescence: The Philips cathodoluminescence (CL) detector has a spectral response of 20%QE from 275 to 600nm.
- Controlled pressure: The specimen chamber pressure may be controlled in the range from 0.1 to 1mBar, allowing the analysis and (BSE) imaging of insulators, hydrated samples or uncoated specimens without charging artifacts.
- Stage: 50*50mm eucentric stage featuring motorised control of x, y, z and rotation.
- The PGT Spirit EDS X-ray anlysis system allows qualitative and quantitative analysis as well as X-ray imaging of samples. The energy dispersive X-ray detector can detect elements heavier than and including Carbon.
- The HKL Channel5 EBSD system enables the determination of crystallographic orientation data.
- Images: All images may be stored using either a high resolution digital frame store (1404*968 or 702*484) or high resolution phototube. Digital (.tif) images may be exported to CD or USB memory stick. Output devices include a laser printer and a thermal video printer.
- Operating System: All microscope, X-ray and EBSD analysis systems operate via a computer using the Windows operating system.
- Sample preparation including impregnation, cutting, grinding and polishing equipment.
- Carbon and Gold coating.
- Reflected and transmitted light microscopes with photographic facilities for specimen documentation.
- Optical cathodoluminescence microscope.
- Black & White photographic developing and printing facilities.
- Access to the Electron Microprobe Facility for quantitative major and minor element (0.01 wt%) analysis using either energy dispersive analysis or wavelength dispersive analysis.
- Access to the Ion Microprobe Facility for isotopic and trace element (ppm) analysis.
The Facility also has the necessary support equipment:
댓글 0
번호 | 제목 | 글쓴이 | 날짜 | 조회 수 |
---|---|---|---|---|
공지 | 회사 목록 | 모아레 | 2011.02.07 | 18148 |
공지 | 연락처 목록 | 모아레 | 2010.08.05 | 323 |
공지 | 유용한 사이트 | 모아레 | 2010.02.25 | 5620 |
공지 | 메모 정리 (미완) | 모아레 | 2009.10.30 | 236 |
공지 | 연구실 장비 목록 | 모아레 | 2009.09.30 | 840 |
공지 | 주문, 구입 리스트 | 모아레 | 2009.09.21 | 483 |
공지 | To do list, Short Memo | 모아레 | 2009.08.20 | 496 |
52 | 반도체 기초자료 - Lithography 등 | 모아레 | 2011.01.17 | 148 |
51 | XML 강좌 | 모아레 | 2011.02.07 | 148 |
50 | Etch rate of GaAs | 모아레 | 2010.11.10 | 146 |
49 | Cryo pump 원리 - 플래시 | 모아레 | 2010.05.07 | 146 |
48 | Vacuum can 제작할 때 참고할 것. | 모아레 | 2009.08.19 | 142 |
47 | 컴퓨터 오류 | 모아레 | 2010.11.15 | 140 |
46 | 연구실 연락처 | 모아레 | 2009.06.23 | 134 |
45 | AlN properties, Resonance 기초 | 모아레 | 2010.12.13 | 133 |
44 | 물질안전보건자료(MSDS)란? | 모아레 | 2009.08.28 | 133 |
43 | KPS 초록 | 모아레 | 2010.10.02 | 132 |
42 | E-Beam Lithography 자료 | 모아레 | 2010.01.13 | 131 |
41 | 중전 Windows XP EN 시디키 | 모아레 | 2010.01.25 | 130 |
40 | 레지스트 조사 | 모아레 | 2009.07.19 | 127 |
39 | Ashing Test | 모아레 | 2010.05.18 | 125 |
38 | About Network Analyzer Calibration | 모아레 | 2010.08.16 | 123 |
37 | Piezoelectric materials | 모아레 | 2010.11.12 | 121 |
36 | COMSOL 교육 결제 공지 | 모아레 | 2010.08.23 | 119 |
35 | pirahna solution | 모아레 | 2010.09.01 | 117 |
34 | Litho 관련 용어 정리 | 모아레 | 2009.07.08 | 116 |
33 | Developers (MIF, MIC) | 모아레 | 2010.08.13 | 115 |