http://www.geos.ed.ac.uk/facilities/sem/specification.html
The SEM facility operates a Philips XL30CP with PGT Spirit X-ray analysis and HKL Channel5 Electron Backscatter Diffraction (EBSD) systems. The specification of the instrument is:
- Electron Gun: A tungsten filament source produces a stable and high current electron beam, ideal for x-ray analysis as well as imaging.
- Resolution: The resolution of the microscope is 3.5nm at 30kV using the secondary electron (SE) detector.
- Backscatter: The backscatter (BSE) detector allows the imaging of specimens that have a mean atomic number difference of >0.1.
- Cathodoluminescence: The Philips cathodoluminescence (CL) detector has a spectral response of 20%QE from 275 to 600nm.
- Controlled pressure: The specimen chamber pressure may be controlled in the range from 0.1 to 1mBar, allowing the analysis and (BSE) imaging of insulators, hydrated samples or uncoated specimens without charging artifacts.
- Stage: 50*50mm eucentric stage featuring motorised control of x, y, z and rotation.
- The PGT Spirit EDS X-ray anlysis system allows qualitative and quantitative analysis as well as X-ray imaging of samples. The energy dispersive X-ray detector can detect elements heavier than and including Carbon.
- The HKL Channel5 EBSD system enables the determination of crystallographic orientation data.
- Images: All images may be stored using either a high resolution digital frame store (1404*968 or 702*484) or high resolution phototube. Digital (.tif) images may be exported to CD or USB memory stick. Output devices include a laser printer and a thermal video printer.
- Operating System: All microscope, X-ray and EBSD analysis systems operate via a computer using the Windows operating system.
- Sample preparation including impregnation, cutting, grinding and polishing equipment.
- Carbon and Gold coating.
- Reflected and transmitted light microscopes with photographic facilities for specimen documentation.
- Optical cathodoluminescence microscope.
- Black & White photographic developing and printing facilities.
- Access to the Electron Microprobe Facility for quantitative major and minor element (0.01 wt%) analysis using either energy dispersive analysis or wavelength dispersive analysis.
- Access to the Ion Microprobe Facility for isotopic and trace element (ppm) analysis.
The Facility also has the necessary support equipment:
댓글 0
번호 | 제목 | 글쓴이 | 날짜 | 조회 수 |
---|---|---|---|---|
공지 | 회사 목록 | 모아레 | 2011.02.07 | 18105 |
공지 | 연락처 목록 | 모아레 | 2010.08.05 | 322 |
공지 | 유용한 사이트 | 모아레 | 2010.02.25 | 5606 |
공지 | 메모 정리 (미완) | 모아레 | 2009.10.30 | 235 |
공지 | 연구실 장비 목록 | 모아레 | 2009.09.30 | 837 |
공지 | 주문, 구입 리스트 | 모아레 | 2009.09.21 | 481 |
공지 | To do list, Short Memo | 모아레 | 2009.08.20 | 491 |
12 | KPS 초록 | 모아레 | 2010.10.02 | 130 |
11 | Noise (in audio amplifiers) | 모아레 | 2010.10.08 | 449 |
10 | Etch rate of GaAs | 모아레 | 2010.11.10 | 144 |
9 | Piezoelectric materials | 모아레 | 2010.11.12 | 120 |
8 | 컴퓨터 오류 | 모아레 | 2010.11.15 | 139 |
7 | Nonlinear resonance | 모아레 | 2010.11.30 | 224 |
6 | AlN properties, Resonance 기초 | 모아레 | 2010.12.13 | 132 |
5 | 반도체 기초자료 - Lithography 등 | 모아레 | 2011.01.17 | 145 |
4 | 참고 사이트 | 모아레 | 2011.02.01 | 201 |
3 | XML 강좌 | 모아레 | 2011.02.07 | 148 |
2 | PS/2 케이블 and 어댑터 | 모아레 | 2011.02.07 | 1160 |
1 | MALDI 설명 | 모아레 | 2011.02.13 | 14489 |