http://www.geos.ed.ac.uk/facilities/sem/specification.html
The SEM facility operates a Philips XL30CP with PGT Spirit X-ray analysis and HKL Channel5 Electron Backscatter Diffraction (EBSD) systems. The specification of the instrument is:
- Electron Gun: A tungsten filament source produces a stable and high current electron beam, ideal for x-ray analysis as well as imaging.
- Resolution: The resolution of the microscope is 3.5nm at 30kV using the secondary electron (SE) detector.
- Backscatter: The backscatter (BSE) detector allows the imaging of specimens that have a mean atomic number difference of >0.1.
- Cathodoluminescence: The Philips cathodoluminescence (CL) detector has a spectral response of 20%QE from 275 to 600nm.
- Controlled pressure: The specimen chamber pressure may be controlled in the range from 0.1 to 1mBar, allowing the analysis and (BSE) imaging of insulators, hydrated samples or uncoated specimens without charging artifacts.
- Stage: 50*50mm eucentric stage featuring motorised control of x, y, z and rotation.
- The PGT Spirit EDS X-ray anlysis system allows qualitative and quantitative analysis as well as X-ray imaging of samples. The energy dispersive X-ray detector can detect elements heavier than and including Carbon.
- The HKL Channel5 EBSD system enables the determination of crystallographic orientation data.
- Images: All images may be stored using either a high resolution digital frame store (1404*968 or 702*484) or high resolution phototube. Digital (.tif) images may be exported to CD or USB memory stick. Output devices include a laser printer and a thermal video printer.
- Operating System: All microscope, X-ray and EBSD analysis systems operate via a computer using the Windows operating system.
- Sample preparation including impregnation, cutting, grinding and polishing equipment.
- Carbon and Gold coating.
- Reflected and transmitted light microscopes with photographic facilities for specimen documentation.
- Optical cathodoluminescence microscope.
- Black & White photographic developing and printing facilities.
- Access to the Electron Microprobe Facility for quantitative major and minor element (0.01 wt%) analysis using either energy dispersive analysis or wavelength dispersive analysis.
- Access to the Ion Microprobe Facility for isotopic and trace element (ppm) analysis.
The Facility also has the necessary support equipment:
댓글 0
번호 | 제목 | 글쓴이 | 날짜 | 조회 수 |
---|---|---|---|---|
공지 | 회사 목록 | 모아레 | 2011.02.07 | 18151 |
공지 | 연락처 목록 | 모아레 | 2010.08.05 | 323 |
공지 | 유용한 사이트 | 모아레 | 2010.02.25 | 5621 |
공지 | 메모 정리 (미완) | 모아레 | 2009.10.30 | 236 |
공지 | 연구실 장비 목록 | 모아레 | 2009.09.30 | 840 |
공지 | 주문, 구입 리스트 | 모아레 | 2009.09.21 | 483 |
공지 | To do list, Short Memo | 모아레 | 2009.08.20 | 496 |
31 | Litho 관련 용어 정리 | 모아레 | 2009.07.08 | 116 |
30 | 레지스트 조사 | 모아레 | 2009.07.19 | 128 |
29 | COMSOL 시뮬레이션 참고자료 | 모아레 | 2009.07.30 | 105 |
28 | Circuit Quantum Electrodynamics | 모아레 | 2009.08.07 | 260 |
27 | 아세톤 메탄올 IPA 사용에 관한 포스트 | 모아레 | 2009.08.18 | 5335 |
26 | 물질안전보건자료(MSDS)란? | 모아레 | 2009.08.28 | 133 |
25 | 그라핀 | 모아레 | 2009.09.02 | 61 |
24 | 오실로스코프의 이해와 올바른 사용법 | 모아레 | 2009.09.13 | 744 |
23 | Hall effect | 모아레 | 2009.09.26 | 80 |
22 | 나노 재료에서의 screening effect | 모아레 | 2009.10.30 | 448 |
21 | BOE(Buffered oxide etch) | 모아레 | 2010.01.11 | 1354 |
20 | Silox Vapox III | 모아레 | 2010.01.11 | 396 |
19 | E-Beam Lithography 자료 | 모아레 | 2010.01.13 | 131 |
» | SEM specification | 모아레 | 2010.01.26 | 12503 |
17 | 전자 부품 | 모아레 | 2010.01.26 | 77 |
16 | Coplanar Waveguide | 모아레 | 2010.01.31 | 98 |
15 | Device fabrication and measurement techniques | 모아레 | 2010.01.31 | 204 |
14 | Thermo-Electric Model of a VCSEL Die | 모아레 | 2010.01.31 | 78 |
13 | 교내개발 소프트웨어 배포 - snu메일 | 모아레 | 2010.02.23 | 2138 |
12 | Cryo pump 원리 - 플래시 | 모아레 | 2010.05.07 | 146 |